Scientific Analytical Instruments

Leading Manufacturer of digital laboratory stirrer microprocessor based, 3 point micro processor based ph meter, microprocessor based automatic digital ph meter, temperature humidity data logger, digital conductivity tds meter and conductivity & tds meter 3 point calibration from Vadodara.

Digital Laboratory Stirrer Microprocessor based

Request Callback

₹ 8900 / Piece Get Latest Price

MaterialMild Steel
Model NameOLSD-13
Model NumberOLSD-13
BrandOptima
Max. Stirring Capacity10 Litres
Speed Range [rpm]500-9500 RPM
Weight4
Warranty12 Months
Stirring PositionsMiddle
Protection ClassIndustry Standards

Minimum order quantity: 1 Piece

Laboratory Stirrer – Vertical

Digital RPM & Timer – LCD Display

Micro-Processor based Unit.  

Speed: 500 -9500 RPM

Capacity: 10 Liters

3 Point Micro Processor Based pH Meter

Request Callback

₹ 13600 / Piece Get Latest Price

Product Brochure
Type Of Ph MeterTable-Top
Usage/ApplicationLaboratory
CalibrationAuto Calibration
Automation GradeAutomatic
BrandOptima
Model No.Opti Gold 533
Display Type16 x 2 alpha numeric LCD display
Standard Accessories:
  • Combination pH electrode
  • Temperature probe
  • Stand with clamp
  • Dust cover
  • Operation manual

Special Features :
  • Microprocessor based design
  • High degree of accuracy 0.01 pH
  • Auto/man. temp. compensation
  • Auto buffer for quick analysis
  • High input impedance
  • Auto polarity decimal
  • Compact light weight
  • Display pH/mV/TEMP
  • Soft touch keys for operation
  • Optional printer interfacing

Specifications:
  • Range: 0.00 to 14.00 pH
  • Resolution: 0.01 pH
  • Accuracy: 0.01 pH ± 1 digit
  • Input Impedance: 1012 ohms
  • Buffer Calibration: 7.00 pH, 4.00 pH ond 9.20 pH.
  • Temperoture Ronge: 0-100°c with continuous digital display
  • Resolution: 1.0° c
  • Temp. Compensation: Automatic Manual
  • Display: 16 Charater X 2 Lines Liquied Crystal Display
  • Polarity Decimal: Automotic
  • Supply: 220V AC ± 10%, 50Hz
  • Dimenssion: 180mm x 130mm
  • Weight: 750 gm. in Plastic Cabinet
  • Optional: Printer interface (extra charges)

Microprocessor Based Automatic Digital PH Meter

Request Callback

₹ 13600 / Piece Get Latest Price

Type Of Ph MeterPortable
BrandOptima
Usage/ApplicationLaboratory
CalibrationAuto Calibration
Display TypeDigital
Voltage220 V
Frequency50 Hz
Dimension180 mm x 130 mm
Special Features:
  • High degree of accuracy 0. 01 ph
  • Error indication for buffers & slope
  • Auto/man. Temp. Compensation
  • Auto buffer for quick analysis
  • High input impedance
  • Auto polarity & decimal
  • Compact & light weight
  • Display ph/mv/temp.
  • Soft touch keys for operation
  • Optional printer interfacing

Specifications:

Ph mode Mv mode
Range 0. 00 to 14. 00 ph 0 to + 1999 mv
Resolution 0. 01 ph + 1 mv
Accuracy 0. 01 ph + 1 digit 1 mv + 1 digit
Input impedance
Buffer calibration 7. 00 ph,4. 00 ph,9. 2 ph
Temperature Range 0-100 c with continuous digital display
Resolution 1. 0 c
Temp. Compensation Automatic & Manual
Display 16 character x2 lines liquid crystal display
Polarity & Decimal Automatic
Supply
Dimenssion
Weight
Optional Printer Interface (extra changes)


Standard Accessories:

  • Combination ph electrode (gel filled unbreakable type)
  • Temperature Probe
  • Stand with clamp
  • Dust cover
  • Operation manual
  • Ph meter (flame proof optional)
  • Orp meter
  • Conductivity indicators
  • Tds indicators
  • Turbidity
  • Flame photometer
  • Spectrophotometer
  • All type of process & laboratory electronic instruments meter

Applications:
pH meter are used for testing the ph value of acid and alkali. It is a basic instruments for every chemical user for quality management of in put raw material sand finished products drugs & pharm.
  • Dyes & intermediates
  • Food & fertilizers
  • Water, waste water & soli
  • Paper & pulp
  • Research & quality analysis
  • Pathological analysis
  • Electroplating
  • Chemical lab in school & colleges.

Temperature Humidity Data Logger

Request Callback

₹ 7800 / Number Get Latest Price

Type Of Data LoggerDigital Data Logger
Usage/ApplicationIndustrial
Parameter To Be MonitoredHumidity
InterfaceUSB
Export Of DataPDF
DisplayLCD
No. Of ChannelsDual Channel, Multichannel, Single Channel
Power SupplyBattery
Pc Connectionyes
We Optima Instruments are one of the prominent manufacturers, exporters and suppliers of Analytical Instruments & Systems, Laboratory Instruments  and many more. Our range fulfill the needs of dues & intermediate, educational institute, petrochemical, pharmaceutical, research, chemical and healthcare field

Digital Conductivity Tds Meter

Request Callback

₹ 9800 / Piece Get Latest Price

Product Brochure
Weight1.5 kg in Aluminium Cabinet
Voltage230 V
Dimension205 mm x65 mm x 130 mm
Frequency50 Hz
Environment Temperature0 to 50 Degree C
Specification:

Frequency Source In built automatically selected.
Selectable Range Conductivity: 0-20 µs / cm , 200 µs / cm, 2 ms / cm & 200 ms/cms TDS : 0-20 ppm, 200 ppm, 2 ppt & 200 ppt
Measuring Accuracy + 1% of F.S. in all ranges +/- 1 count @ 20 ° C.
Indication 3.5 digit LED
Calibration Single point manually
Decimal Automatic selection
Conductivity Cell approx 1.0 cell constant with plastic protective cover (optional 0.1 cell)


Standard Accessories Conductivity cell, stand rod clamp dust cover & manual

Conductivity & TDS Meter 3 Point Calibration

Request Callback

₹ 24750 / Unit Get Latest Price

Model Name/NumberOICM-20
BrandOptima
Measure Range0-200000 ppm
Usage/ApplicationLaboratory
Accuracy100 %
Resolution0.1 PPM
Warranty1 Year
Display TypeLCD
We Optima Instruments are one of the prominent manufacturers, exporters and suppliers of Analytical Instruments & Systems, Laboratory Instruments  and many more. Our range fulfill the needs of dues & intermediate, educational institute, petrochemical, pharmaceutical, research, chemical and healthcare field

Auto Karl Fischer Titrimeter

Request Callback

₹ 30000 / Piece Get Latest Price

Country of OriginMade in India

Minimum order quantity: 1 Piece

Manual karl fischer Titration Apparatus

Bod Direct Measurement System

Request Callback

₹ 180000 / Piece Get Latest Price

BrandOptima
MaterialPlastic
ShapeRectangular
Automation TypeAutomatic
Applications

Waste Water, Determination of Biological Activity, Waste Water Treatment Plants, Analytical Laboratories, Scientific & Research.


Highlights
  • Direct sample selection
  • Accurate and direct display of BOD values in mg/l
  • User-friendly handling
  • User-selectable measuring period from 1 to 28 days (BOD5, BOD7, OECD…)
  • Storage of all values
  • Measuring ranges from 0-40 mg/l to 0-4000 mg/l BOD, sample volume related
  • Auto start function after temperature equalisation
  • Mercury-free, environmentally-friendly
  • Inductive stirring system with automatic re-centering of stirring rods
  • Interface RS 232

 

Description

The sensor system is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintain-ing a constant volume. Thanks to the modern integral pressure sensors, it is no longer necessary to use mercury for pressure measurements.


Biochemical Oxygen Demand (BOD)

BOD – biochemical oxygen demand – is an expression for the quantity of oxygen required for biological degradation of organic matter in a waste water sample. BOD measurement is therefore used as a basis for the detection of biologically degradable organic matter in water. The difference between BOD and chemical oxygen demand (COD) is that COD additionally registers biologically non-degradable organic matter. BOD measurement is therefore an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points.

Dispensing and Sampling Booth

Request Callback

₹ 135000 / Piece Get Latest Price

BrandOptima
MaterialStainless Steel
Air Flow90 FPM (0.45 m/s) 10 FPM (0.05 m/s)
Noise Level65.5 dB

Minimum order quantity: 1 Piece

Specifications:

Filters:Aluminum framed High efficiency Particulate air (HEPA),Mini Plate with a minimum efficiency of 99.99% at 0.3 micron.

Hepa Filter: Aluminum framed High efficiency Particulate air (HEPA) with a minimum efficiency of 99.99% at 0.3 micron.

Pre filter: Washable type pleated 10 Micron pre-filter with 90% efficiency. EU4 rating.

Construction: Models available in 18 gauge (1.2 mm) stainless steel 304.

Air flow: 90 FPM (0.45 m/s) 10 FPM (0.05 m/s) average velocity measured 6 in. (152.4 mm) from the diffuser screen. Uniformity 20% of average or better

Pressure: Magnehelic pressure differential gauge Omicron USA Make

Noise level: 65 5 DB measured from filter face.

Motor / Blower assembly: Direct drive, continuous duty ¼ HP with sealed bearings. Motor assembly is mounted on M.S.casing to reduce noise & vibration and is dynamically balanced.

Plenum: In stainless steel 304 for distribution of air. Designed in negative pressure to prevent escape and / or bypass of HEPA filter by contaminated air and / or dust

X

Contact Us

Praful Jethva (CEO)
Optima Instruments
Fifth Floor, 501, Vihav Trade Centre, Canal Ring Road
Vadodara - 391410, Gujarat, India

Get Directions
Send Email
Share: