Product Details:
Type Of Ph Meter | Table-Top |
Usage/Application | Laboratory |
Calibration | Auto Calibration |
Automation Grade | Automatic |
Brand | Optima |
Model No. | Opti Gold 533 |
Display Type | 16 x 2 alpha numeric LCD display |
Product Details:
Type Of Ph Meter | Portable |
Brand | Optima |
Usage/Application | Laboratory |
Calibration | Auto Calibration |
Display Type | Digital |
Voltage | 220 V |
Frequency | 50 Hz |
Dimension | 180 mm x 130 mm |
Ph mode | Mv mode | |
Range | 0. 00 to 14. 00 ph | 0 to + 1999 mv |
Resolution | 0. 01 ph | + 1 mv |
Accuracy | 0. 01 ph + 1 digit | 1 mv + 1 digit |
Input impedance | ||
Buffer calibration | 7. 00 ph,4. 00 ph,9. 2 ph | |
Temperature Range | 0-100 c with continuous digital display | |
Resolution | 1. 0 c | |
Temp. Compensation | Automatic & Manual | |
Display | 16 character x2 lines liquid crystal display | |
Polarity & Decimal | Automatic | |
Supply | ||
Dimenssion | ||
Weight | ||
Optional | Printer Interface (extra changes) |
Standard Accessories:
Product Details:
Weight | 1.5 kg in Aluminium Cabinet |
Voltage | 230 V |
Frequency | 50 Hz |
Dimension | 205 mm x65 mm x 130 mm |
Environment Temperature | 0 to 50 Degree C |
Frequency Source | In built automatically selected. |
Selectable Range | Conductivity: 0-20 µs / cm , 200 µs / cm, 2 ms / cm & 200 ms/cms TDS : 0-20 ppm, 200 ppm, 2 ppt & 200 ppt |
Measuring Accuracy | + 1% of F.S. in all ranges +/- 1 count @ 20 ° C. |
Indication | 3.5 digit LED |
Calibration | Single point manually |
Decimal | Automatic selection |
Conductivity Cell | approx 1.0 cell constant with plastic protective cover (optional 0.1 cell) |
Standard Accessories | Conductivity cell, stand rod clamp dust cover & manual |
Product Details:
Model Name/Number | LMPH-10 |
Brand | Optima |
Measure Range | 0-200000 ppm |
Usage/Application | Laboratory |
Accuracy | 100 % |
Resolution | 0.1 PPM |
Warranty | 1 Year |
Display Type | LCD |
Product Details:
Brand | Optima |
Material | Plastic |
Shape | Rectangular |
Automation Type | Automatic |
Waste Water, Determination of Biological Activity, Waste Water Treatment Plants, Analytical Laboratories, Scientific & Research.
Description
The sensor system is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintain-ing a constant volume. Thanks to the modern integral pressure sensors, it is no longer necessary to use mercury for pressure measurements.
BOD – biochemical oxygen demand – is an expression for the quantity of oxygen required for biological degradation of organic matter in a waste water sample. BOD measurement is therefore used as a basis for the detection of biologically degradable organic matter in water. The difference between BOD and chemical oxygen demand (COD) is that COD additionally registers biologically non-degradable organic matter. BOD measurement is therefore an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points.
Product Details:
Type Of Data Logger | Digital Data Logger |
Usage/Application | Industrial |
Parameter To Be Monitored | Humidity |
Interface | USB |
Export Of Data | |
Display | LCD |
No. Of Channels | Dual Channel, Single Channel, Multichannel |
Power Supply | Battery |
Pc Connection | yes |
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Optima |
Material | Stainless Steel |
Air Flow | 90 FPM (0.45 m/s) 10 FPM (0.05 m/s) |
Noise Level | 65.5 dB |
Specifications:
Filters:Aluminum framed High efficiency Particulate air (HEPA),Mini Plate with a minimum efficiency of 99.99% at 0.3 micron.
Hepa Filter: Aluminum framed High efficiency Particulate air (HEPA) with a minimum efficiency of 99.99% at 0.3 micron.
Pre filter: Washable type pleated 10 Micron pre-filter with 90% efficiency. EU4 rating.
Construction: Models available in 18 gauge (1.2 mm) stainless steel 304.
Air flow: 90 FPM (0.45 m/s) 10 FPM (0.05 m/s) average velocity measured 6 in. (152.4 mm) from the diffuser screen. Uniformity 20% of average or better
Pressure: Magnehelic pressure differential gauge Omicron USA Make
Noise level: 65 5 DB measured from filter face.
Motor / Blower assembly: Direct drive, continuous duty ¼ HP with sealed bearings. Motor assembly is mounted on M.S.casing to reduce noise & vibration and is dynamically balanced.
Plenum: In stainless steel 304 for distribution of air. Designed in negative pressure to prevent escape and / or bypass of HEPA filter by contaminated air and / or dust