Product Details:
Brand | Optima |
Resolution | 1/0.1/0.01 |
Temperature Accuracy | +/-0.5 degree C |
TDS Factor | 0.0-1.0 |
pH Range | 2.000-20.000pH |
Make | OPTIMA |
---|---|
pH Range | -2.000-20.000pH |
Resolution | 0.001, 0.01, 0.1pH, Selectable |
Accuracy | ±0.002 pH |
Calibration Points | Up to S points |
pH Buffer Groups | USA, (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18112.45), DIN (pH1.09/4.6516.79/9.23/12.75) |
ORP (mV) Range / Calibration | 0 - ±1999.9mV / 1. point |
Resolution | 0.1, /1mV, Selectable |
Accuracy | ±0.2mV |
Measuring Mode | Absolute mV or Relative mV |
Conductivity Range | 0-200mS/cm |
Accuracy | ±0.5% Full Scale |
Cell Constant | 0.1 / 1 / 10 / User defined |
Temperature Coefficient | 0.0-10.0% per t |
Calibration Points | Up to 5 points |
Calibration Solutions | 10uS/cm, 84u5/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm |
Compensation Modes | Linear or Pure Water |
TDS Range | 0-10ppt ( Max.200 ppt, Depending on factor setting ) |
Resolution | 0.01 / 0.1 / 1 |
Accuracy | ±1% Full Scale |
TDS Factor | 0.0-1.0 |
Salinity Range | 0-80ppt |
Resolution | 0.01 / 0.1 /1 |
Accuracy | ±1% Full Scale |
Accuracy | Measurement Mode |
Measuring Mode | Practical Salinity (PSU) or Seawater Measurement Standard (ppt) |
Resistivity Range | 0-100M0 |
Resolution | 1/0.1/0.01 |
Accuracy | ±1% Full Scale |
Temp. Range | 0-105°C, / 32-221°F |
Temp. Compensation | 0-100°C, 32-212°F, Automatic or Manual |
Temp. Accuracy | ±0.5°C, ±0.9°F |
Auto-Off Function | 10 / 20 / 30 minutes after last key pressed |
Reset & Auto Hold Function | Yes |
Electrode Diagnosis | Slope, Offset |
Stability Conditions | High or Low, Selectable |
Calibration due reminder | 1 to 30 days, Selectable |
Memory | 500 data sets with Date/Time |
Output & Connector | USB Communication Interface & BNC / 6-pin codsvnnector |
Dimensions (LxWxH)& Weight |
Product Details:
Usage/Application | Laboratory |
Brand | Optima |
Resolution | 0.1, 0.01 ppm, (Selectable) |
Dissolved Oxygen Range | 0.00-20.00mg/L or ppm |
Dissolved Oxygen Accuracy | +0.2mg/L or ppm |
Saturation of Oxygen | 0.0-200.0% |
Make | Optima Instruments |
---|---|
Dissolved Oxygen Range | |
Accuracy | ± 2.0% |
Temperature Range | 0.0-50.0°C |
Temperature Accuracy | ± 0.5°C |
Temperature Compensation | 0-50°C, Automatic |
Salinity Correction | 0-50g/L |
Barometric Pressure Correction | 60.0-112.5kPa, 450-850mmHg |
Calibration Points | 1 0r 2 points (100% in air or 0% in zero oxygen solution) |
Memory & Output | 500 data sets with Date/Time stamping & USB Interface |
Power Supply | DC 5V adapters, using AC 220V/50Hz |
Dimensions LxWxH (mm) & Weight | 210 x 188 x 60 & 1.2 kg |
Product Details:
Brand | Optima |
Timer | 999 minutes |
Speed | 1250 RPM |
Max Volume | 2000 ml |
Voltage | 220 V |
Frequency | 50 Hz |
Weight | 2.3 Kg |
Product Details:
Hole Size (mm) | 40 mm |
Display | LED, Digital |
Application | Industrial Use, Laboratory Use |
Material | MS Powder Coated |
Sensor | RTD |
Portable | Yes |
Glassware | Included |
Power (W) | 1.5 kw |
Control | Digital control thru Auto Tune PID Controller |
Sample Volume (ml) | 20 ml |
Voltage (V) | 230 V AC |
Temperature (deg. Celsius) | 200 degree cent |
Power Source | Single Phase |
Weight (kg) | 15 Kg |
Heater Load (kW) | 1.5 kw |
Number Of Holes | 6 / 9/12 /18/ 15 / 21 / 24 |
Condition | New |
Brand | Optima |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | OI-6530 |
Brand | Optima |
Packaging Type | Safe Box packing |
Measure Range | Cond. - 0 ~ 500mS/cm & TDS : 0-250000 ppm |
Usage/Application | Industrial |
Accuracy | 0.01 microS /cm and 0.01 ppm |
Warranty | 1 Year |
Resolution | 0.01 ppm |
Batteries | No |
Features | Automatic with 4-20 mA & RS -485 output |
Industrial on-line conductivity meter is an on-line water quality monitoring and control instrument with microprocessor.The instrument is widely used in power plant, petrochemical, metallurgy, electronics, mining, paper, semiconductor, medicine, food and beverage, environmental water treatment, new agricultural planting and other industries.Suitable for softened water, raw water, steam condensate, sea water distillation and deionized water, etc.The conductivity value, resistivity value, TDS value, salinity and temperature value of aqueous solution were continuously monitored and controlled.
Instrument features:
large LCD screen color LCD display
smart menu operation
data record & curve display
manual or automatic temperature compensation
three groups of relay control switches
high limit, low limit, hysteresis control
4-20ma &RS485 multiple output modes
the same interface displays the measured value, temperature, current value, etc
can set password protection to prevent non-staff error operation
Technical parameters:
(1) measurement range:
Conductivity: 0 ~ 500mS/cm;
The resistivity: 0 ~ 18.25 M Ω/cm;
TDS: 0 ~ 250g/L;
Salinity: 0 ~ 700PPT;
0 ~ 70%;
0 ~ 700 g/L;
Temperature: -10 ~ 150.0???;
(2) resolution:
Electrical conductivity: 0.01 refresh /cm;0.01 mS/cm;
The resistivity: 0.01 K Ω/cm;0.01 M Ω/cm;
TDS: 0.01 mg/L;0.01 g/L;
Salinity: 0.01PPT;0.1%;0.01 mg/L;
Temperature: 0.1???;
(3) basic error: ±0.5%F.S;
Temperature: ±0.3???;
(4) stability: ±0.2%F.S/24h;
(5) two-channel current output:
0/4 ~ 20 ma (load resistance < 750 Ω);
20 ~ 4 ma (load resistance < 750 Ω);
(6) communication output: RS485 MODBUS RTU;
(7) three groups of relay control contacts:
5A 250VAC, 5A 30VDC;
(8) power supply:
85 ~ 265VAC±10%,50±1Hz, power ≤3W;
9 ~ 36VDC, power: ≤3W;
(9) appearance size: 215*125*80mm;
(10) installation method: wall-mounted;
(11) protection level: IP65;
(12) instrument weight: 1.5kg;
(13) working environment:
Ambient temperature: -10 ~ 60???;
Relative humidity: no more than 90%;
There is no strong magnetic field around except the earth's magnetic field.
Additional Information:
Product Details:
Model | MP-30 |
Brand | Optima |
Warranty | 1 Year |
Resolution | 10 PPM |
Application | Laboratory |
Product Details:
Mobility | Portable |
Brand | Imported |
Model No / Item Code | OI-722 |
Power Source | Electric |
Usage / Application | Laboratory Use |
Material | ABS |
Product Details:
Wavelength Range | 325-1100 nm |
Mobility | Portable |
Brand | Optima |
Model No / Item Code | Oi-721 |
Display | Digital |
Material | ABS plastic |
Frequency Range | 40 to 50 Hz |
Product Details:
Wavelength Range | 190-1100 nm |
Optical System | Single Beam |
Spectral Bandwidth | 0.5/1/2/4/5nm |
Brand | Optima |
Model No / Item Code | I-290 |
Photometric Repeatability | 0.1%T(0~100%T) |
Display | Digital |
Usage / Application | Food Analysis |
Material | ABS plastic |
Product Details:
Wavelength Range | 325-1100 nm |
Optical System | Double Beam |
Mobility | Portable |
Brand | Optima |
Model No / Item Code | OI-2904 |
Color | Black |
Material | ABS Plastic |
Product Details:
Mobility | Portable |
Brand | Optima |
Model No / Item Code | Ls-2700 |
Display | Digital |
Material | ABS |
Frequency | 40/50 Hz |
Product Details:
Optical System | Single Beam |
Mobility | Portable |
Brand | Optima instrument |
Model No / Item Code | OI-295 |
Power Source | Electic |
Voltage | 110-240 V |
Product Details:
Temperature Range | 10 to 60 Degree C |
Humidity Range | 40% rh to 98% rh |
Phase | Single Phase |
Voltage | 220-320 V |
Outer Material | Mild Steel |
inner Material | Stainless Steel |
Applications:
Working size | |
Material of construction : inside s. S. & outside s. S. Inside s. S. & outside gi powder coat finish. | 50 x 50 x 50 x cm. Ht. |
Humidity range : 40% rh to 98% rh | 50 x 50 x 70 x cm. Ht. |
Temp. Range # : 10 °c to 60 °c | 60 x 60 x 90 x cm. Ht. |
Accuracy temp. / rh : + 0. 20c & + 3% rh | 1m3 |
( # Low temp. Range : -25 °c / -15 °c / -10 °c & 0 °c & 35% rh on request. ) | (Bigger size on request) |
Product Details:
Brand | Optima |
Material | Stainless Steel |
Voltage | 230V |
Automation Type | Automatic |
Frequency | 50Hz |
Product Details:
Brand | Optima |
Usage/Application | Laboratory |
Frequency | 40/50 Hz |
Power Source | Electric |
Voltage | 210-240 V |
Product Details:
Wavelength Range | 190-1100 nm |
Optical System | Single Beam |
Mobility | Portable |
Brand | Optima |
Model No / Item Code | OI-285 |
Voltage | 110-240 V |
Material | ABS plastic |
Frequency Range | 40 to 50 Hz |
Product Details:
Brand | Optima |
Wavelength Range | 190nm-850nm |
Optical Range | 0.02-300 ABS |
Measure Speed | 2-5 Seconds |
Product Details:
Usage/Application | Laboratory |
Brand | Optima |
Model | OIAR-1317 |
Application | Laboratory |
Usage Temperature Ra | Ambient to 35 Degree C |
Interface | RS232 |
Dimensions | 370 x 240 x 470 mm |
Voltage | 220V |
Weight | 12kg |
Frequency | 50 Hz |
Make | LABMAN |
---|---|
Measurement range Refractive index nD | 1.3000-1.7000 |
Measurement range dissolved solids Brix | 0.100% |
Accuracy refractive index nD | < ±0.0002, |
Accuracy dissolved solids Brix | ±<0.1% |
Temperature resolution | 0.1°C |
Temperature range (Min 0.1°C) | 0.-50°C |
Correction range of Brix versus Tempereture | 15-45°C |
Product Details:
Minimum Order Quantity | 1 Unit |
Type of PH Meter | Table-Top |
Brand | Optima |
Usage/Application | Laboratory |
Type | Digital |
pH Range | 0-14 pH |
Product Details:
Type Of Ph Meter | Portable |
Usage/Application | Laboratory |
Display Type | Digital |
Calibration Interval | 6 Months |
Ph Meter Type | Handheld Portable Meter |
Brand | Optima |
Product Details:
Usage/Application | Laboratory |
Brand/Make | Optima |
Automatic Grade | Automatic |
Material | Metal |
Frequency | 50 Hz |
Voltage | 230V |
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | Optima |
Application | Laboratory |
Light Source | Sodium Lamp |
Material | ABS Plastic |
Interface | RS232 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model | OICM-20, OICM-20 |
Brand | Optima |
Measure Range | 0-200000 ppm |
Usage/Application | Laboratory |
Accuracy | 0.1 ppm |
Humidity | 95 % rH Non condensation |
Voltage | 230 V AC |
Resolution | 0.1 PPM |
Probe | Yes |
Auto Cell Constant Measurement | 0.1; 1.0 ; 10.0 Cell Constant |
Cell Constant | 0.1; 1.0 ; 10.0 Cell Constant |
Display Type | LCD |
Measurable Conductivity Range | 0-200 mS/cm |
Number Of Ranges | 5 ranges |
Power | 230 V AC |
Type Of Temperature Compensation | ATC - Automatic |
No. Of Calibration Points | 3 |
Tds Factor | Adjustable |
Temperature Coefficient | Adjustable |
Cond. Range | 0-200 mS/cm |
Readout | LCD |
Tds Range | 0-200000 ppm |
Retransmission Output | No |
Body Material | ABS |
Data Storage | No |
Country of Origin | Made in India |
Usage | Laboratory |
Additional Information:
Product Details:
Usage/Application | Laboratory |
Usage | Laboratory |
Tilting Angle | 30 to 90 Degree |
Voltage | 220V |
Wattage | 3W |
Product Details:
Usage/Application | Laboratory |
Brand | Optima |
Material | Aluminium Alloy |
Shape | Square |
Weight | 3 Kg |
Voltage | 230V |
Dimension | L 274 X B 320 X H 167 mm |
Magnification | x 1.7 |
Magnifying Glass Diameter | 100 mm |
Digital Readout | 0-9999 |
Product Details:
Usage/Application | Laboratory |
Brand | Optima |
Material | Metal |
Illumination | Halogen |
Packaging Type | Box |
Objectives | 4 x,10 x,20 x 40 x and 60 x |
Wattage | 100 W |
DC Voltage | 12V |
Product Details:
Minimum Order Quantity | 01 Piece |
Brand | Optima |
Material | Mild Steel |
Shape | Rectangular |
Automation Type | Automatic |
Phase | Single Phase |
Operating Voltage | 220 V |
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | Optima |
Application | Laboratory |
Measurement Range | -60~+60 Degree C |
Output Current | 4-20 mA |
Housing | SS |
Product Details:
Minimum Order Quantity | 1 Piece |
Design | Modern |
Size (length x Width) | 48"x21" |
Material | SS |
Height | 4-6 Feet |
Brand | Optima |
No of Wheel | 4 Wheel |
PSI-069 Tissue Culture Rack
Tissue culture rack are very useful for various types of tissue culture plants and other tissue culture work in tissue culture room.
Made By : Tissue rack are made of tubular mild steel pipes With Epoxy Powder Coated.
Racks Specification : Each rack of size 48"x21" (depth) is covered with thick glass or Acrylic. Distance between each rack is 15".
Lighting : Four fluorescent tubes are glare free lights are built in upper portion in worktable.
UV Germicidal Light : Are fitted inside the rack.
Chocks : All fluorescent tubes chocks and ultra violet germicidal tube chocks are fitted out side of rack.
Timer : 0-24 Hours Digital Timers are provided of tissue culture rack.
Control Panels : All control panels are fitted tops of tissue culture racks. On/Off switch of fluorescent tubes and UV tubes. All control panels are fitted separately in each rack with indicator light.
Easy Mobility : The whole rack is provided with four nos. castor wheels at the bottom for easy mobility to any place.
Product Details:
Usage/Application | Laboratory |
Type Of Sterilizer | Ethylene Oxide Sterilizer |
Grade Standard | Chemical Grade |
Automatic Grade | Automatic |
Material | ABS |
Voltage | 210-280 V |
Product Details:
Brand | Optima |
Automation Grade | Manual |
Packaging Type | Box |
Voltage | 210-240 V |
Frequency | 40/50 Hz |
Product Details:
Brand | Optima |
Application Media | Any Liquid |
Frequency | 50 Hz |
Voltage | 230 V |
Power Source | Electric |
Body Material | ABS Plastic |
Current | 3.5A |
Product Details:
Usage/Application | Laboratory |
Brand | Optima |
Magnification | 1000 X |
Material | Metal |
Automation Grade | Semi-Automatic |
Product Details:
Usage/Application | Laboratory |
Brand | Optima |
Magnification | 50-100X |
Frequency Speed | 1GHz |
Working Voltage | 12V |
Product Details:
Thickness | 15-20 mm |
Material | Mild Steel |
Brand | Optima |
Automation Grade | Manual |
Product Details:
Brand | Optima |
Usage/Application | Laboratory |
Resolution | 0.001,0.01,0.1pH ( Selectable ) |
Type Of Ph Meter | Bench Type |
pH Range | 2.000 - 20.000pH |
Accuracy | +/-0.002pH |
SPECIFICATION | MAKE | LABMAN |
---|---|---|
pH Range & Accuracy | -2.000 - 20.000pH & ±0.002pH | |
Resolution | 0.001,0.01,0.1pH ( Selectable ) | |
Ion Concentration Range | 0.001-19999 ppm,mg/L,mol/L (Selectable Depending on meas. Range of Ion Selective Electrode) | |
Ion Concentration Accuracy | ±0.5% Full Scale ( Monovalent),±1% Full Scale (Divalent) | |
mV Range & mV Accuracy | -.11999.9 mV & ±0.2mV | |
Resolution | 0.1/1mV, Selectable | |
Temperature Range & Accuracy | 0-105°C, 32-221°F & ±0.5°C,±0.9T | |
Calibration Points | Ion / pH : Up to 5 Points | |
pH Buffer Groups | USA (011.68,4.01,7.00,10.01 ,12A5), NIST (pH1.68,4.01,6.86,9.18,12.45), DIN (011.09,4.65,6.79,923,12.7 OR User Define) | |
Memory and Output | 500 data sets with Date/Time stamping, USB Communication interface. | |
Connector & Hold Function | BNC & Selectable | |
Temperature Compensation | 0-100t,32-212 F,Automatic or Manual | |
Stability Conditions | Low or High, Selectable | |
Calibration due reminSder | 1 to 31 days or Off | |
Power Supply | DC 5V adapters, using AC 220V / 50Hz, | |
Dimensions LxWxH (mm) & Weight | 210 x 188 x 60 & 1.2kg |
| "LABMAN" - COMBINATION | ION SELECTIVE | ELECTRODES |
|
Electrodes | Concentration Range ( molar) | Limits (ppm) | Temperature Ranget | Main Interferences |
Calcium [ Ca++ ] | 10-1 to 5.10-7 | 4,010 to 0.02 | 5 to 50 | Ba, Al, Sr |
Chloride [ Cl- ] | 1 to 5.10-5 | 35,500 to 1.8 | 5 to 50 | I, Br, CN, S |
Fluoride [ F- ] | 10-'' to 10-6 | 1,900 to 0.02 | 5 to 50 | OH |
Nitrate [ NO3 ] | 1 to 7.10-6 | 62,000 to 0.4 | 5 to 50 | CI, NO |
Bromide [ Br ] | 1 to-5.10-6 | 81,000 to 0.4 | 5 to 50 | I, S, CN |
Sodium [Na''] | 1 to .10-5 | 23000 to 0.2 | 5 to 50 | Li, K |
Cadmium [ Cd++ ] | 1-1 to 10-6 | 11200 to 0.1 | 5 to 50 | Ba, Cu, Ag, Hg |
Iodide [ N ] | 1-1 to 10-5 | 127000 to 1.2 | 5 to 50 | S, CN |
Product Details:
Minimum Order Quantity | 1 Piece |
Country of Origin | Made in India |
Usage/Application | Laboratory |
Model Name/Number | OI-B18 |
Operating Temperature | 0-60 Degree Celsius |
Measuring Range | 3% to 40% |
Warranty | 1 Year |
Accuracy | +/- 0.5% throughout the measuring range |
Brand | Optima |
Moisture Range | 3% to 40% |
Material | ABS Plastic Body |
Optima Instruments is a pioneer in the field of instruments for agriculture, oil and food industry. Our instruments have been established very well in industry and are considered very well in industry and are considered industry standards.
Specification:
Salient Features:
Additional Information: