Optima Instruments
Optima Instruments
Sayajiganj, Vadodara, Gujarat
SEND SMS
SEND EMAIL

Analytical Instruments & Systems

Prominent & Leading Manufacturer from Vadodara, we offer digital ph indicator, online ph indicator, process orp indicator, digital conductivity indicator optieco, conductivity controller and online dissolved oxygen electrode.

Digital pH Indicator

Digital pH Indicator
  • Digital pH Indicator
Get Best Quote
Approx. Price: Rs 6,500 / NoGet Latest Price

Product Details:

Resolution0.01pH
pH Range0-14 pH
Accuracy+/-1% Of Full Scale
Voltage220 V
No of Digits3.5 Digit
Frequency50 Hz

Specifications:
  • Sensor(Flow Type): ½” BSP thread or 3/4″ BSP thread
  • Size: 48 x 96 x 110mm or 96 x 96 x 65mm ( Black Color ABS P lastic Housing, Panel Mount)
  • Environment: 5 to 50°C
Request
Callback


Additional Information:

  • Item Code: pH-Opti-Eco
Yes! I am Interested

Online pH Indicator

Online pH Indicator
  • Online pH Indicator
Get Best Quote
Approx. Price: Rs 3,500 / NumberGet Latest Price

Product Details:

Minimum Order Quantity1 Number
Resolution0.01pH
Automation GradeSemi-Automatic
BrandOptima
Current1 A
ApplicationIndustrial
pH Range0-14 pH
Accuracy0.1pH +/- 1 digit Of reading
Voltage220V
Dimension96x96x110mm
Environment Temperature5 to 50 Degree C
Frequency50Hz

Specifications:
  • Dual Display: Upper For pH (Red LED) Lower for Temp. (Green LED)
  • Temp.Compensation: 0-150 ° C Auto Manual ( PT-100)
  • Input impedance: 1012 Ohms,
  • Calibration: 3 point Auto Calibration 7.0, 4.0 9.2
  • Error Indication: Out Off BuffersRange. (B) Slope Error
  • Control Setting: Two Set Point ( High Low)
  • Controlling Output: One Changeover Relay of Potential Free Contacts Of 2 Amp
  • Compatible with other make pH electrodes also.
Request
Callback
Yes! I am Interested

Process ORP Indicator

Process ORP Indicator
  • Process ORP Indicator
Get Best Quote
Approx. Price: Rs 9,500 / PieceGet Latest Price

Product Details:

Accuracy0.2 % of Range
Input Impedance1012 Ohms
Range0 To +/- 1999 mVs
Resolution+/- 1 mV
Repeatability+/- 1 mV
Display TypeLED
Voltage220 V
Frequency50 Hz

Specifications:
  • Control Setting: Single set point (press to set)
  • Control Output: Single changeover Relay potential from contacts of 5 Amps.
  • ORP Assembly: ORP Sensor fitted in assebly available in S.S 316 or rigid PVC
  • Size (Panel Mounting Type): 72x144x120mm (Metal Cabinet), Panel Cutout 66mmx137 mm
Request
Callback


Additional Information:

  • Item Code: ORP-Optiplus
Yes! I am Interested

Digital Conductivity Indicator OptiEco

Digital Conductivity Indicator OptiEco
  • Digital Conductivity Indicator OptiEco
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price

Product Details:

Display TypeLED
Voltage220 V
Size48 x 96 x 110mm or 96 x 96 x 65mm
Resolution0.01micro, 0.1micro, 1micro, 10micro, 100micro
No of Digit3.5 Digit
Body MaterialABS Plastic
Frequency50 Hz

Specifications:
  • Single Range: 19.99micro, 199.9micro, 1999micro, 19.99mili, 199.9mili. ( Select Any One Range, Required)
  • Accuracy: ± 1% Of Full Scale
  • Cell ( Flow Type): ½” BSP thread or 3/4″ BSP thread ( Cell Constant 0.8 to 1.3)
  • Environment: 5 to 50°C
Request
Callback
Yes! I am Interested

Conductivity Controller

Conductivity Controller
  • Conductivity Controller
Get Best Quote
Approx. Price: Rs 8,500 / PieceGet Latest Price

Product Details:

Display Size96 x 96 x 110mm
Frequency50Hz
Voltage230 V
Resolution0.01micro, 0.1micro, 1 micro, 10 micro, 100 micro
Environment Temperature5 to 50 Degree C
Body MaterialABS Plastic

Specifications:

  • Single Range" 19.99micro, 199.9micro, 1999micro, 19.99mili, 199.9mili. ( Select Any One Range Required)
  • Accuracy: ± 1% Of Full Scale
  • Display: Upper Display For Conductivity( Red LED) Lower Display for
  • Set Value ( Green LED), If ATC It’s Show Tem
  • Control Setting: Two Set Point ( High Low)
  • Controlling Output: One Changeover Relay of Potential Free Contacts of 2 Amp
  • Cell ( Flow Type): ½”BSP thread or 3/4″ BSP thread ( Cell Constant 0.5 to 3.0)
  • Optional Facility At Extra Cost: Auto Temp. Compensation, 4-20mA Output, Printer Output ( RS 232)
Request
Callback


Additional Information:

  • Item Code: Opticon
Yes! I am Interested

Online Dissolved Oxygen Electrode

Online Dissolved Oxygen Electrode
  • Online Dissolved Oxygen Electrode
Get Best Quote
Approx. Price: Rs 1.2 Lakh / PieceGet Latest Price

Product Details:

Weight670 g
Temperature Sensor22 kOhms NTC
Shaft Diameter12 mm
Flow Rate20 mm/sec
Dissolved Oxygen Range0.04 ppm to saturation
Pressure Rating4 bar (58 psi)

Specifications:
  • Operating Temperature: 0 to 60 ºC / 32 to 140 ºF
  • Material: Stainless steel
  • Membrane: Non-replaceable
  • Cable: 5 m (16.4 ft) fixed and sealed
Request
Callback
Yes! I am Interested

Electrochemical Monitor

Electrochemical Monitor
  • Electrochemical Monitor
Get Best Quote
Approx. Price: Rs 3,500 / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
Response Time10 s for 98% of input
Voltage220 V
Current5 A
Relay Delay0.0/99.9 s
BrandOptima
Dimension96x96x155 mm

Add the following to the common Features/Specifications of the 7685 Series shown overleaf:

  • Input from preamplified sensor
  • Manual, automatic and simulated operation
  • Selectable scales:
  • 0/4.000 0/40.00 0/400.0 0/4,000 NTU
  • 0/4.000 0/40.00 0/400.0 0/4,000 mg/lt of PSL
  • 0/9.999 0/99.99 0/999.9 0/9,999 mg/lt of SiO2
  • Autoranging
  • Dual filter software
  • Alphanumeric backlit display
  • 0/20 or 4/20 mA selectable output, programmable on the
  • input scale
  • 2 Set point with min/max function, hysteresis and
  • adjustable delay
  • Coninuous/flashing alarm
  • Alarm: min/max turbidity, set point timing, dirty lens,
  • empty cell, external light too high
  • Check signal of dirty lens
  • Autoclean relay with programmable cycle repetition,
  • cleaning and holding time
  • 3 access levels: display, calibration and configuration of
  • process parameters
  • Panel mounting
  • This instrument is designed to operate together with TU 810, TU 8105 and TU 8182 amplified Turbidity probe which can be installed over 100 m far from the controller. In addition, the software allows to use the probe TU 820 (USEPA 180.1 method). Accessories allow the system to operate in flow, in line and in immersion applications.

Specifications:

  • Operating mode: Automatic/Manual
  • Measuring unit: NTU/mg/l
  • Range: 4/400 NTU – 40/4,000 NTU
  • 4/400 – 40/4,000 mg/lt of PSL
  • 9/999 – 99/9,999 mg/l of SiO2
  • Filter software 90%RT: 5/220 s for small/large variations
  • Zero of the probe: 0.0/10.0 % f.s.
  • Sensitivity: 80.0/120.0 %
  • Set point A/B: ON-OFF
  • Hysteresis: 0/10 % of the scale
  • Low/high alarm: 0 to full scale
  • Autoclean: Manual/Auto+Manual
  • Analog output: 0-20/4-20 mA isolated
  • R max: 600 ohm
  • Serial output: RS232 option 091.701
  • Humidity: 95% without condensate
  • Power: 110/220 Vac +/-10% 50/60 Hz 5 VA max
  • Isolation: 4000 V (IEC 348)
  • Dimensions: 96x96x155 mm (1/4 DIN)

Options:

  • 091.3713: Dual analog output
  • 091.4141: 9/36 VDC power supply

Meauring probes:

  • TU 810 – TU 820
  • Turbidity probe in PVC body
  • TU 8105
  • Turbidity probe in PVFD body
  • TU 8182
  • Turbidity probe autoclean submersible in PVC body

Accessories:

  • SZ 9481 Connector + 10 m cable
  • SZ 9483 Connector + 30 m cable
  • TU 910 Flow cell for TU 810, TU 8105 or TU 820
  • Formazine Standard solutions
Request
Callback
Yes! I am Interested

Online Dissolved Oxygen (DO) System

Online Dissolved Oxygen (DO) System
  • Online Dissolved Oxygen (DO) System
Get Best Quote
Approx. Price: Rs 85,000.00 / NoGet Latest Price

Product Details:

Power2w at 25 Degree C
DC Voltage18-36 V
Measurement Range0 to 40 ppm
Resolution0. 01 ppm
Input Voltage10 to 30 V

Av38

Functions and Features

  • Connects to any Datastick System.
  • Convenient ¼ din enclosure.
  • Display sensor and temperature data.
  • Menu Functions: Calibration, Configuration and Diagnostics.
  • Digital protocol options for remote measurement, calibration, configuration and diagnostics.
  • Two 4 to 20 ma loop outputs.
  • Two form c relays for Alarm, Control and Wash.
  • Pid with ph.
  • 7 conduit knockouts for easy Cabling. Mounting options Conduit box, Nema 4x.
  • ½ din nema 4x panel mount.
  • Display only with nema 4x gasket.
Av88

Functions and Features

  • Connects to any analogplus sensor using plug in module.
  • Convenient ¼ din enclosure.
  • Display sensor and Temperature Data.
  • Menu functions: Calibration, Configuration and Diagnostics.
  • Digital protocol options for remote measurement, calibration, configuration and diagnostics.
  • Two 4 to 20 ma loop outputs.
  • Two form c relays for alarm, control and wash.
  • pid.
  • 7 conduit knockouts for easy cabling.
  • Mounting options conduit box, nema 4x.
  • ½ din nema 4x panel mount.
  • Display only with nema 4x gasket.

Hot63

Ranges of Measurement

  • 0 - 199. 9% saturation
  • 0 - 20. 00ppm
  • Accuracy ± 3. 0ua in galvanic mode
  • ± 1. 0na in polargraphic mode
  • Linearity ± 0. 1% of range
  • Repeatability ± 0. 1% of range
  • Display: 4*7 alphanumeric large display (backlit)
  • Housing: ip66, conductive abs blue plastic
  • Output: selectable 0/4-20 ma
Do Sensorsanalogplus Do
  • Polarographic sensor design
  • Replacement membrane cartridges for long life


Measurement System Performance

Range:0 to 40 ppm
Resolution:0. 01 ppm
Accuracy:0. 04 ppm

Construction

Process electrodes:Gold Cathode, Silver Anode, Silver Reference
Membrane:Fep Teflon
o-rings:Viton® (Other Materials Available)


e-1733

Polarographic Principle

Body:Cpvc
Temperature:0-80 deg c
Pressure:4 bar atm
Membrane:Ptfe/Silicon
o-Ring Seals:Silicone Rubber
Cathode:Platinum
Anode:Silver
Electrolyte:Koh/kcl Solution
Response Time:98% readout in 60 sec
Connection:0. 75" npt (m) with integral 10ft cable.

Request
Callback
Yes! I am Interested

Online Redox System

Online Redox System
  • Online Redox System
Get Best Quote
Approx. Price: Rs 13,000 / PieceGet Latest Price

Product Details:

PhaseSingle Phase
BrandOptima
Current2 A
Pole TypeSingle Pole
MaterialABS

We offer high quality Online Redox / ORP System(ORP / Redox Indicator / Controllers / Transmitter). These products are known for high efficiency and ensures long term stability and durability.
Request
Callback
Yes! I am Interested

Online Dissolved Oxygen Analyzer

Online Dissolved Oxygen Analyzer
  • Online Dissolved Oxygen Analyzer
Get Best Quote
Approx. Price: Rs 1.2 Lakh / PieceGet Latest Price

Product Details:

Response Time40 to 50 sec
Weight670 gm
Length(Excludes Cable) 152.4 mm
Dissolved Oxygen Range0.03 to 20 ppm
Galvanic Flow Rate50 mm/sec
Diameter58.4 mm

Request
Callback
Yes! I am Interested

Turbidity Probe

Turbidity Probe
  • Turbidity Probe
Get Best Quote
Approx. Price: Rs 1.2 Lakh / PieceGet Latest Price

Product Details:

Response Time10 s
Ambient Temperature0/50 Degree C
Sample Temperature0/50 Degree C
Sample Pressure6 bar max. a 20 Degree C
IP RatingIP 67

Common Specifications:

  • Measuring method: Nephelometric (ISO 7027 – EN 27027)
  • Preamplifier: built-in
  • Power: ± 12 Vdc from TU 7685
  • Optical window material: Acrilic
  • Pipe Tee for direct inline mounting: 2” (DN 50)

TU 810 – TU 8105 Specifications:

  • Range: 0/4000 NTU
  • Resolution: 0.001 on scale 0/4.000 NTU
  • 0.01 on scale 0/40.00 NTU
  • 0.1 on scale 0/400.0 NTU
  • 1 on scale 0/4,000 NTU
  • Accuracy: ± 5% of reading on 0/400 NTU
  • ± 10% of reading on 400/4,000 NTU
  • Light source: LED I.R. 890 nm
  • TU 810 body material: PVC
  • TU 8105 body material: PVDF
  • O Ring: NBR (Acrylat Nitrile)

TU 820 Specifications:

  • Range: 0/400 NTU
  • Resolution: 0.001 on scale 0/4.000 NTU
  • 0.01 on scale 0/40.00 NTU
  • 0.1 on scale 0/400.0 NTU
  • Accuracy: ± 5% of reading on 0/400 NTU
  • Light source: Tungsten lamp 2200 °K
  • Average life of the lamp: 100,000 hours
  • Sensor sensitivity: 600 nm
  • Body material: PVC
  • O Ring: NBR (Acrylat Nitrile)
Request
Callback
Yes! I am Interested

Sievers Innovox

Sievers Innovox
  • Sievers Innovox
Get Best Quote
Approx. Price: Rs 12 Lakh / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
BrandOptima
PhaseSingle Phase
Frequency50-60 Hz
Power SourceElectric
Voltage230-260 V

Features and Benefits:

  • Wide Dynamic Operating Range — Measures up to 50,000 parts per million (ppm).
  • Versatile Measurement Modes — Measures Total Inorganic Carbon (TIC), NPOC, Total Carbon (TC) and TOC by difference (TC-TIC).
  • Sample Handling Robustness — Uses aninnovative Supercritical Water Oxidation(SCWO) technique to achieve superior TOC recoveries regardless of organic compounds and particulate impurities in the sample. The InnovOx can handle awide variety of traditionally difficult sample matrices, including brine, cellulose, and humic acid (see tables on pages 3 and 4) with unprecedented reliability
  • Easy Operation — The InnovOx On-Line offers preset protocols for easy startup. Both On-Line and Laboratory models have intuitive color touch-screen interfaces, and operate immediately without any necessary heater warm-up or detector stabilization.
  • Low Maintenance and Cost of Ownership — Robust by design, the InnovOx requires minimal operator intervention or preventive maintenance, offers up to six months’ calibration stability, and features a solid state nondispersive infrared (NDIR) detector.
  • Ethernet Web browser interface (Lab model) — Allows users to remotely monitor and control Analyzer operations and results using a Web-based interface and the instrument’s Ethernet interface.
  • User-configurable alarms and outputs (On-Line model) — Notifies user of water system events and enables remote monitoring of analysis results and performance.

Key Applications:

  • Petrochemical
  • Food and Beverage
  • Chlor-alkali Chemistry
  • Pharmaceutical
  • Environmental Labs
  • Manufacturing
  • Municipal/Industrial Wastewater
  • Power
  • Research
  • Pulp and Paper
  • Brine and Seawater
  • Unconventional Oil Gas

The innovOx features three main steps,each with significant process innovations:

Sample Handling and Reagent Mixing:

  • The InnovOx ensures superior sample representation and accuracy by processing a large sample volume and thoroughly agitating the sample in the Sample Mixing Chamber. The sample and reagents are added through a unique sample coil delivery system which prevents syringe contamination.
  • Supercritical Water Oxidation (SCWO)
  • Using a patented SCWO technique (see sidebar at right), the Sievers InnovOx takes the water sample to a supercritical state by increasing the temperature, and subsequently the pressure, within the reactor. The properties of supercritical water enable an ultra-efficient, rapid oxidation of organic carbon to carbon dioxide, even in the presence of chloride and other inorganic species that negatively interfere with non-SCWO oxidation.

NDIR Detection:

  • The InnovOx uses a highly stable, nondispersive infrared (NDIR) detector. Unlike other NDIR detectors, the InnovOx NDIR has no moving parts, and features tight temperature control of the IR source and detector
Supercritical Water Oxidation (SCWO):

  • Supercritical Water Oxidation (SCWO) was originally developed to treat large volumes of aqueous waste streams, sludges, and contaminated soils. SCWO destroys organic wastes using an oxidant in water and temperatures and pressures above the critical point of water—375 °C and 3,200 psi. These conditions enable rapid and complete oxidation. Today, SCWO research and development is focused on treating a variety of toxic and hazardous organic wastes.
Request
Callback
Yes! I am Interested

Ph Electrode Sensor

Ph Electrode Sensor
  • Ph Electrode Sensor
Get Best Quote
Approx. Price: Rs 8,500 / PieceGet Latest Price

Product Details:

BrandOptima
Pressure15 PSIG
Cable Length4-6 m
Packaging TypeBox

These sensors are designed for rugged service in submersion or on-line applications. The reference cell features a Double Junction design for extended service life in harsh applications. The body, with integral pipe threads, is molded from chemical-resistant Ryton® (PPS) and the reference junction is porous Teflon® or ceramic. Built-in temperature compensator are available. An optional sensor guard on the front of the sensor protects the sensor tip from impact. The sensor is also available in an ORP (Redox) version.   These high quality sensors are constructed of corrosion-resistant wetted materials including Ryton®, Teflon® and glass. The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning. Includes built-in temperature compensation, built-in solution ground, custom cable lengths and choice of cable connectors.   - PH ELECTRODE – pH Optilab 13
Request
Callback


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: CIF India
  • Production Capacity: per month 150
  • Delivery Time: Ex stoke 2-3 weeks
  • Packaging Details: corrugated box pack or wooden as per customer requirement or based mode of transport.
Yes! I am Interested
View PDF

Online pH Controllers

Online pH Controllers
  • Online pH Controllers
Get Best Quote
Approx. Price: Rs 13,000.00 / NoGet Latest Price

Product Details:

Resolution0.01 pH
Accuracy+/-0.02 pH
Display Type4 Digit LED
Measuring Range0~14 pH

 Panel MountedField Mounted Weather ProofFlame Proof2 wire Transmitter –Weather Proof2 wire Transmitter –Flame Proof
ModelpH OptimaxpH Optiplus-WPpH Optiplus-FLPpHT 204DpH Opti2-FLP
Measuring Range0~14 pH
Display4 Digit LED4  Digit LED4  Digit LED4  Digit LCD3 ½ Digit LCD
Resolution0.01 pH
Accuracy±0.02 pH
Input Impedance5 x  1011 Ω Minimum1012 Ω  Minimum
Temp. CompensationAutomatic / Manual
Output2 Relay (3 Amp.)  for High / Low pH Control (Optional: 4~20mA Isolated) 4~20mA Isolated output, 2 - wire Type
(Load 200W Max.)
Galvanic Isolation : 1500VDC (Input/Output)
Calibration3 Point Auto Calibration Thru. Front Keypad2 Point  Using Offset & Slope Trimmers
Power Supply230 V AC; 50 Hz24VDC ± 10%
 Other Voltages on Request
Operating Temperature & RH0 to 55 °C & 20 % to 95 % RH non-condensing0 to 80 °C& 20 % to 95 % RH non-condensing0 to 55 °C & 20 % to 95 % RH non-condensing0 to 80 °C & 20 % to 95 % RH non-condensing
HousingIndustrial PlasticPolycarbonate Enclosure IP-65*Al.CastPolycarbonate Enclosure IP-65*Al.Cast
Dimension (mm)
(W X H X D)
96 x 96 x 175130  x  210  x 75195 x 400  x 13580  x  50  x  56Dia 102 x 165 mm with 1" or 2" pipe mounting bracket.

Applications

Chemical

Fine & Specialty Chemicals , Bulk & Intermediate Chemicals, Petrochemicals, Polymers, Dyes, Pigments & Inks

Pharma & Biotechnology


Pharma, Biotechnology, Cosmetics, Food Additives

Food & Beverage

Soft Drinks & Juices, Dairy, Sugar, Starch & Yeast, Meat & Poultry, Oil & Fats, Bakery & Confectionery, Agriculture

Pulp, Paper & Textile

Pulp & Paper, Textile

OEMs & Systems Integrators

Water Systems, CIP, SIP fabricators, Process Control Integrators, Fermenter & Bioreactor Manufacturers, Packaging Machinery Manufacturers

Utilities & Environment

Water Utilities, Power Generation, Liquid Waste Management
Request
Callback
Yes! I am Interested

Online Chlorine Gas Analyzer

Online Chlorine Gas Analyzer
  • Online Chlorine Gas Analyzer
Get Best Quote
Approx. Price: Rs 90,000 / PieceGet Latest Price

Product Details:

BrandOptima
Usage/ApplicationLaboratory
Automation GradeAutomatic
Packaging TypeBox

Functions and features

  • Free Chlorine
  • Amperometric Measurement
  • Temperature Compensated
  • Optional ph correction
  • Pre-Calibrated
  • Plug & Play
  • Rugged Teflon Membrane
  • Replaceable Membrane Cap
  • Remote Measurement, Calibration, Configuration, and Diagnostics.
Request
Callback
Yes! I am Interested

On Line pH / Redox Sensors

On Line pH / Redox Sensors
  • On Line pH / Redox Sensors
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price

Product Details:

BrandOptima
Output ImpedanceLess than 250 megohms at 25 Degree C
Maximum Flow Rate10 ft (3 m) per second
ApplicationsIn-Line & Submersion

Specifications:

  • Chemical-resistant Wetted Materials These high quality sensors are constructed of corrosion-resistant wetted materials including Ryton®, Teflon® and glass.
  • Coaxial Porous Teflon® Reference Junction The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.
Request
Callback
Yes! I am Interested

ORP Transmitter

ORP Transmitter
  • ORP Transmitter
Get Best Quote
Approx. Price: Rs 16,000 / PieceGet Latest Price

Product Details:

UsageLaboratory
BrandOptima
Current4-20 mA
Power SourceElectric

We are engaged in manufacturing and supplying of ORP Transmitter from India. These are available in leading industrial prices.
Request
Callback
Yes! I am Interested

Industrial Contacting Conductivity Sensor

Industrial Contacting Conductivity Sensor
  • Industrial Contacting Conductivity Sensor
Get Best Quote
Approx. Price: Rs 1.25 Lakh / PieceGet Latest Price

Product Details:

BrandOptima
MaterialBrass
Length4-6 inch
ShapeRound

Specifications:

  • Heavy duty electrodes for boiler applications cd3
  • Available with ATC Pt 100 for most makes and models of conductivity transmitters
  • or controllers
  • 0.05, 0.1, 1.0 and 10.0 cell constants available
  • Extended length version for mounting in cross
  • OPTIMA  manufactures a quality line of industrial grade conductivity electrodes for sub-
  • mersion or in-line mounting. All electrodes are constructed of stainless steel bodies and
  • pins (SS316) and either teflon or peek insulator. Automatic temperature compensation is
  • available as an option. A
  • pplications may include food, pharmaceutical, high purity water, reverse Osmosis, waste treatment, and other processes.

Engineering Specification:

  • The sensor shall have these important enhanced performance design characteristics:
  • Manufactured to exacting tolerances using high quality, rugged materials.
  • Offers durable 316 stainless steel body conductivity and resistivity sensors with NPT connection mounting.
  • Individually tested to determine its absolute Three-digit cell constant, ensuring highest possible  measuring
  • accuracy.
  • Built to include a Pt 100 [Pt 1000 optional] RTD temperature element within its tip for exceptionally  fast response to changes in Temperature with ± 0.1 C accuracy.
  • It is suitable for operating temperature upto 135
  • C and Pressure upto 100 psig.
  • Available with cell constant of 0.05, 0.1, 1 or 10 and fitting with ¾” NPT male.
  • The sensor shall have an integral 3 M cable, or an integrally mounted junction box (polypropylene, aluminium or 316 stainless steel) that requires optional interconnect cable.
Request
Callback


Additional Information:

  • Item Code: CCST-Series
Yes! I am Interested

Dissolved Oxygen Controller/Transmitter

Dissolved Oxygen Controller/Transmitter
  • Dissolved Oxygen Controller/Transmitter
Get Best Quote
Approx. Price: Rs 13 Lakh / PieceGet Latest Price

Product Details:

Resolution0.01 mg/L ; 0.10 %
Accuracy+/-0.5 Degree C
Temperature CompensationAuto/manual
Dropout Delay0 to 2000 sec

Applications:

  • General: Useful for monitoring temperature and control of DO in wastewater treatment and aquaculture applications. Use with valves, blowers or aerators to ensure proper system operation.

Specifications:

  • Range: 0.00 to 20.00 mg/L ; 0.0 to 200.0 %
  • Accuracy: ±1.5 % of full scale reading
  • Range: -9.9 to 125.0 ºC
  • Resolution: 0.1 ºC
  • Sensor: Pt100 ; 3 wire
  • Salinity Compensation: 0.0 to 50.0 ppt(manual setting and automatic correction)
  • Pressure Compensation: kPa/mmHg (manual setting and automatic correction)
  • Set Point 1 (SP1): 0.00 to 20.00 mg/L or 0.0 to 200.0 %
  • Switching DO Hysteresis: 0.1 to 1.0 mg/L or 0 to 10.0 %
  • Function (Switchable): P control (pulse length/pulse frequency); limit control
  • Adjustable Period With Pulse Length Controller: 0.5 to 20 sec
  • Adjustable Period With Pulse Frequency Controller: 60 to 120 pulse/min
  • Switching Voltage/Current/Power: Max. 250 VAC / max. 3 A / max. 600 VA
Request
Callback
Yes! I am Interested

Chlorine Monitor

Chlorine Monitor
  • Chlorine Monitor
Get Best Quote
Approx. Price: Rs 90,000 / PieceGet Latest Price

Product Details:

Frequency40/50 Hz
Current Outputs4-20 mA or 0-20 mA
Power SourceElectric
Body MaterialAluminium

Implements the DPD colorimetric method to determine chlorine concentration:

  • One point calibration of photometric cell
  • Control time cycles adjustable between 3 to 90 minutes
  • Proportional control of chlorine concentration
  • Out of range measurement and self-diagnostic system alarms
  • Parameter control through analog output or dedicated relays
  • Logging space of up to of 3500 measurements and alarm status
  • Multi-language support
  • RS485 connectivity

The PCA 3X0 series monitors the free chlorine or total chlorine in the 0 to 5.0 mg/L range;
In the DPD Colorimetric method, N, N-Diethyl-p-phenylene-Diamine indicator and a buffer are mixed with the sample. Free available chlorine oxidizes the DPD indicator reagent at a pH between 6.3 and 6.6 to form a magenta colored compound. The intensity of the resulting color is proportional to the concentration of chlorine in the sample. The purpose of the buffer solution is to maintain the proper pH.
In total chlorine measurement (free available chlorine plus combined chloramines), potassium iodide is added. The chloramines in the sample cause the iodide ions to become iodine which reacts with free chlorine to oxidize the DPD indicator. A pH of 5.1 is required for this reaction. Thus total chlorine measurements require a different buffer solution containing potassium iodide. Once the chemical reaction is completed, the optical signal at 555 nm is compared to the signal measured through the sample before the reagents were added. From these measurements chlorine concentration is calculated and shown on the display.
Indicator and buffer reagent bottles are placed directly into the instrument case. With a sampling period of 5 minutes, reagents need only to be replenished about once a month.

Chlorine/Bromine/Iodine Control:

  • Four chlorine/bromine/iodine level set points can be adjusted by the operator: a proportional dosing set point, two alarm set points and a minimum level for dosing. The proportional dosing factor (1/Δ) is user selectable with a delta between 0.1 and 2 pH. Chlorine/ bromine/iodine dosing system controls a SPST relay. Each alarm can be enabled or disabled.

pH Control:

  • Three pH level set points can be adjusted by the operator: a control set point and two alarm set points. The pH control mode is user selectable; on/off or proportional dosing. The proportional dosing factor (1/Δ) is user selectable with a delta between 0.1 and 2 pH. The on/off dosing hysteresis is user selectable between 0.05 and 2.00 pH. The pH dosing system controls a SPST relay.
  • Each pH, ORP and temperature alarm can be enabled or disabled, and two alarm levels can be set by the user also for temperature and ORP. Alarm condition controls a SPDT relay. The system error feature activates a relay to signal the need for operator intervention. System error condition controls a SPST relay.

Analog Output:

  • Two current outputs of 4-20 mA or 0-20 mA are available to drive external devices such as chart recorders. The analyzer can drive two dosing pumps through the 4-20 mA outputs for chloride and acid/alkali dosing. The analog output is fully programmable and can be proportional with chlorine concentration, pH, ORP or temperature value. The limits of the analog output is selectable for each parameter.

Order Information:

  • Each PCA 300 series model is supplied with reagent bottles (2), reagent caps (2), 1 DPD compound powder, tubing and instructions.
  • PCA 310-1 Free total chlorine analyzer/control (115V) PCA 310-2 Free total chlorine analyzer/control (230V)
Request
Callback
Yes! I am Interested

Online Total Organic Carbon System

Online Total Organic Carbon System
  • Online Total Organic Carbon System
Get Best Quote
Approx. Price: Rs 9 Lakh / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
Limit of Detection0.05 ppm NPOC
Dynamic Range50,000 ppm
Accuracy+/-3%
Sample Temperature Range10-60 Degree C (50-140 Degree F)

Specifications:
  • Analysis Modes: TIC, NPOC, TC, TOC (TC-TIC)
  • Precision: RSD ≤ 1.5%
  • Linearity: R2 ≥ 0.995, measured as NPOC (see Operation Maintenance Manual for calibration recommendation)
  • Analysis Time: 2.6 to 9.2 min, depending on mode
  • Calibration Stability: Up to 6 months
  • Particle Diameters in Sample: ≤ 800 μm diameter
  • Ambient Operating
  • Temperature Range: 10–40 °C (50–104 °F)
  • Maximum Relative Humidity: Up to 95%, non-condensing
  • Sample Inlet Pressure: Ambient
  • Drain: Gravity drain
Request
Callback
Yes! I am Interested

Turbidity Flow Cell

Turbidity Flow Cell
  • Turbidity Flow Cell
Get Best Quote
Approx. Price: Rs 35,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity01 Piece
Flow of Sample0.2/25 l/min
Temperature of Sample0/50 Degree C
Pressure of Sample6 bar max. a 20 Degree C
MaterialPVC

Turbidity Flow Cell is measuring cell which has been designed for using with TU 810, TU 820 or TU 8105 turbidity probes. It allows very accurate measurements even at very low turbidity values, as requested by drinking water applications. It is provided with a flow control to avoid air bubbles from grab samples under pressure. Cleaning and calibrating operations are very easy.

The package includes the 1892702 adaptor and O Ring 2713118
for the TU 810 – TU 820 – TU 8105 installation.

Specifications:
  • Applications: in flow measurement
  • Collar nut thread diameter: 2 1/2”
  • Fittings: 1/4″
  • Tubing: PVC 4×6 mm l=5m
Request
Callback
Yes! I am Interested

Flame Proof PH Indicator - Controller - Transmitter

Flame Proof PH Indicator - Controller - Transmitter
  • Flame Proof PH Indicator - Controller - Transmitter
Get Best Quote
Approx. Price: Rs 18,000 / NumberGet Latest Price

Product Details:

Minimum Order Quantity01 Number
BrandOptima
ModelpH Optiplus
ApplicationIndustrial

Specifications:

  • Range: 0-14 pH
  • Resolution: 0.01digit
  • Accuracy: 0.1pH +/- 1 digit Of reading,
  • Dual Display: Upper For pH (Red LED) Lower for Temp. (Green LED)
  • Temp.Compensation: 0-150 ° C Auto Manual ( PT-100)
  • Input impedance: 1012 Ohms,
  • Calibration: 3 point Auto Calibration 7.0, 4.0 9.2
  • Error Indication: Out Off BuffersRange. (B) Slope Error
  • Control Setting: Two Set Point ( High Low)
  • Controlling Output: One  Changeover Relay of Potential Free Contacts Of 2 Amp
  • Environment: 5 to 50 ° C
  • Supply: 220v A.C +/- 10%, 50Hzs A.C
  • RetransmissionOut. : 4-20 mA Galvanically Isolated (optional) at 650 ohms
Request
Callback


Additional Information:

  • Production Capacity: 200 units per month
  • Delivery Time: ex-stock or 1-2 weeks
  • Packaging Details: corrugated box packing
Yes! I am Interested
View PDF

Dissolved Oxygen 2-Wire Transmitter

Dissolved Oxygen 2-Wire Transmitter
  • Dissolved Oxygen 2-Wire Transmitter
Get Best Quote
Approx. Price: Rs 1.20 Lakh / each unitGet Latest Price

Product Details:

Minimum Order Quantity01 each unit
BrandOptima
Accuracy+/-0.5 Degree C
Range0.0 to 100.0 Degree C

Specifications:

  • Range: 0 to 19.99 mg/L / 0.00 to 19.99 ppm 0 to 199.9 % saturation
  • Accuracy: ±1.5 % full scale
  • Sensor: Pt100; 2 or 3 wire
  • Compensation: Auto/manual (0 to 50 ºC)
  • Salinity Compensation: 0.0 to 50.0 ppt(manual setting and automatic correction)
  • Pressure Compensation: kPa/mmHg (manual setting and automatic correction)
  • Set Point 1 (SP1): 0.00 to 20.00 mg/L or 0.0 to 200.0 %
  • Switching DO Hysteresis: 0.1 to 1.0 mg/L or 0 to 10.0 %
  • Function (Switchable): P control (pulse length/pulse frequency); limit control
  • Adjustable Period With Pulse Length Controller: 0.5 to 20 sec
  • Adjustable Period With Pulse Frequency Controller: 60 to 120 pulse/min
  • Pickup/Dropout Delay: 0 to 2000 sec
  • Switching Voltage/Current/Power: Max. 250 VAC / max. 3 A / max. 600 VA
Request
Callback
Yes! I am Interested

Online Turbidity Analyzers

Online Turbidity Analyzers
  • Online Turbidity Analyzers
Get Best Quote
Approx. Price: Rs 1.2 Lakh / PieceGet Latest Price

Product Details:

ApplicationLaboratory Use
BrandOptima
Mounting TypeWall Mounting
Power SourceElectric

Request
Callback
Yes! I am Interested

Combined Platinum ORP Sensor

Combined Platinum ORP Sensor
  • Combined Platinum ORP Sensor
Get Best Quote
Approx. Price: Rs 9,500 / PieceGet Latest Price

Product Details:

Range+/- 1999 mV
BrandOptima
Temperature Range0-100 degree C
Pressure Range0-5 Kg. /Cm2 rdx2

Request
Callback


Additional Information:

  • Item Code: eH-13
Yes! I am Interested

Force Proving Instruments Load Cell Proving Ring Dynometer

Force Proving Instruments Load Cell Proving Ring Dynometer
  • Force Proving Instruments Load Cell Proving Ring Dynometer
Get Best Quote
Approx. Price: Rs 8.9 Lakh / UnitGet Latest Price

Product Details:

MaterialStainless Steel
ShapeRound
Proving Ring Thickness10-20 mm
Surface FinishedPolished

Request
Callback
Yes! I am Interested
X

Explore more products



Reach Us
Praful Jethva (CEO)
No. 303, Silverline Complex
Sayajiganj, Vadodara- 390005, Gujarat, India



Call Us

Share Us

F GT L


Send E-mailSend SMS